Specifications Min Typ Max Units
Power Supply Voltage    10.0    -    28.0    Vdc
Power Supply Current    (no load)    45    60    mA
Input Threshold    1.96    2.00    2.04    Vdc
Input Voltage (continuous)    -28    -    43    Vdc
Input Voltage (transient)    -250    -    250    Vdc
Output Voltage    0.000    -    6.000    Vdc
Full Scale Frequency (Vout = 6.000V) 8 cylinder mode       400       Hz
Full Scale Frequency (Vout = 6.000V) 6 cylinder mode       300       Hz
Full Scale Frequency (Vout = 6.000V) 4 cylinder mode       200       Hz
Full Scale Frequency (Vout = 6.000V) External pot mode (minimum)       480       Hz
Full Scale Frequency (Vout = 6.000V) External pot mode (maximum)       1600       Hz
Accuracy       0.5    1.0    %
Output Current (per channel)       10       mA
Operating Temperature Range    -40       +70    deg C

 